Performance, cost and efficiency issues associated with bearings com­monly used in today’s wind turbine gearbox high-speed output and intermediate shafts can be addressed with a bearing type for wind turbine gearboxes called the locator bearing, which offers an alternative solution.

The locator bearing combines a single-row tapered roller bearing (TRB) that supports prevailing radial and thrust loads across raceways during the normal positive torque conditions, with a carefully designed secondary rib ring to support thrust loads in reverse torque conditions such as braking or motoring. This single-row bearing type can act as a substitute for different bearing combinations.

Gearbox output shafts are sometimes equipped with a non-locating cylindri­cal roller bearing (CRB) and an axially locating four-point-contact-ball (FPCBB), see Figure 1. The CRB sup­ports only radial load while the FPCBB supports the en­tire thrust load in the system.

Wind turbine gearbox bearing arrangement

Figure 1 – Current bearing arrangement

In Figure 2 another bearing arrange­ment is displayed applying two single-row (similar or dissimilar series) TRBs at the locating position. Special attention is paid to selection of the proper raceway an­gles to insure that both bear­ings rows maintain sufficient size load zones during the full spectrum of operating conditions.

Figure 2 – Bearing arrangement with two tapered roller bearings

Inadequacies in Existing Arrangement

Designed with point contact, the FPCBB is designed primarily for supporting radial load and to a cer­tain degree for moderate thrust loads. This bear­ing design is not ideally suited to support the constant and fluctuating gear thrust loads that are prevalent during nor­mal operation. Under pure axial loading, the balls con­tact the race at an angle and rotate across that contact angle, but at the same time around the cen­terline of the shaft. This causes micro slipping between the balls and raceways introducing sur­face initiated damage modes such as the peeling shown in Figure 3.

Figure 3 – Peeling on balls

The outer ring of the ball bearing must be loosely fitted in the housing to prevent any radial load from transmitting into this bearing. This re­quires keyways to prevent ro­tation of the outer ring: unlike the locator bearing, which is tightly clamped between housing shoulder and end cap.

The arrangement shown in Figure 2 is a good alternative to four-point-contact-ball combinations, although adequate distribution of load and traction forces between the bearing rows remain a design concern.

Locator Bearing Design

Figure 4 shows a typical locator bearing design. In Fig­ure 5, a locator bearing is fixed at the right end of the shaft to support radial and thrust loading from the gear, while a CRB is floating at the opposite end. The bearing re­sembles a single-row tapered roller bearing having an ad­ditional rib ring attached to the outer race.

Figure 4 – Typical configuration of locator bearing

Figure 5 – Bearing arrangement with locator bearing

Figure 6 illustrates how the locator bearing supports thrust load in both the directions. The major thrust (thick arrow line) is due to predominant helical gear thrust that is present during positive torque conditions for more than 99% of the duty cycle. Support of the loads is across the raceways. The tapered roller bearing ac­commodates the combined loading with pure rolling mo­tion without any of the micro slip that takes place with the ball bearing.

Figure 6 – Load sharing


However, occasional faults in the grid or generator, and resonance during braking procedures will force reverse thrust for short intervals. In other cases the generator serves as a motor to drive the turbine rotor at low speed for maintenance, and in some cases of low wind, just at the cut-in speed. All of these conditions re­quire the locator bearing to support axial load in minor direction (thin arrow line, Figure 6). This mi­nor thrust load is transmitted through roller large and small ends, the inner race rib, and the outer race rib ring.

The primary features and benefits of the locator bear­ing include:

1) Reduced axial space compared with two-row arrangements.

2) Easy adaptability to existing designs.

3) Improved gear contact positioning due to the cen­tering characteristic of the locator bearing operating with 360º load zone.

4) Reduced system cost.

5) Reduced stress and increased bearing life because of the 360º load zone and all the rollers are in contact as illustrated in Figure 7, throughout the full range of positive torque during normal power generation.


Figure 7 - 360° load zone

6) Optimized race/roller contact angle based on the ratio of radial (Fr) and axial load (Fa). Careful attention is given to the bearing design so that the thrust induced by the radial reaction on the locator is always less than the gear thrust. Since the ratio of the bearing radial reaction and the gear thrust will be constant for the duty cycle, the gear thrust will always be sufficient to keep the bearing seated.

7) Smaller outer flange is available on either end of the outer race to prevent possibility of reversing orientation during assembly (Figure 8).

Figure 8 – Bearing with locating outer flange

8) Internal clearance is precisely set at the bearing manufacturer. Hence, manual bearing setting during as­sembly is completely eliminated.

9) The range of axial endplay should be closely controlled to insure proper run­ning clearance throughout the spectrum of operating load and temperature conditions. Since the fixed locator bear­ing is used in conjunction with a floating CRB, the need for manual adjustment is eliminated.

10) According to AGMA 6006, allowable maximum contact stress at equivalent load should not exceed 1300 MPa at the output shaft and 1650 MPa at intermediate shaft bearings. Contact stress in a locator bearing supporting both radial and axial load is less than this and much less than that of the CRB that supports only radial load with reduced load zone (see Figure 9).

Figure 9 – Comparison of contact stress

Locator Bearing Configuration

Standard locator bearings are designed with an above centerline cage that retains the rollers with the inner race. Alternatively it can also be provided with a below centerline cage that retains the rollers with the outer race. Such a configuration can be supplied with two separable rib rings (see Figure 10). Preferred construc­tion is largely dependant on the gearbox assembly pro­cedure, mainly when assembling heavy intermediate shafting in a vertical orientation in the housing.

Figure 10 – Locator with two detachable ribs

High-speed shafts are often subject to service inspec­tion and change out. So it is an advantage that the entire output shaft assembly with locator bearing attached can be  slid out the housing during inspec­tion.

Debris Resistant Bearings

Wind turbine gearboxes have a history of bearings and gears experiencing early damage and fatigue. Because the output shafting experiences many more rev­olutions, the bearings on this shaft are even more vulnera­ble to contamination effects. To improve the re­liability, the locator bearing can be supplied with debris resistant bearing materials and ES300 coatings on rollers. Figure 11 shows one such set of experimental results with statistical significance that bearing life can be improved by a factor of 4.5 when the ES300 coating is applied.

Figure 11 – Fatigue life test result: ES300 technology


Although the locator bearing is best suited to high-speed low thrust environment such as gearbox high speed and high-speed intermediate shafts, it has some limitations that restrict its use in other applications. This bearing type cannot tolerate internal bearing preload under any condi­tion. The axial capacity of the bearing in minor direction across the ribs is limited compared to the generous axial capacity in major direction across the raceways. Howev­er the minor axial thrust capacity is very similar to the axi­al capacity of NJ style CRB’s, which have found wide usage in wind turbine gearboxes. It’s interest­ing to note that bi-directional bearings like the loca­tor have been applied in many automotive and aerospace applications exposing them to thrust loads in the minor di­rection with very good success. These operating regimes of load and speed are well established. So the primary challenge to wind turbine gearbox designers is to be able to identify their entire duty cycle so that the locator perfor­mance can be evaluated under all known circumstances. In the end, application testing of the locator in the gear box should be conducted to verify is performance.


While the four-point-contact-ball bearing and cylindrical roller bearing combination have found wide spread usage at the high speed output shaft positions in wind turbine gear boxes, output shaft bearing reliability still remains a weaker part of the system design. Fxed two-row tapered roller bearings are now finding favor. The lo­cator is one more alternative to be considered for the out­put shaft fixed location. Narrower than the wider two-row alternatives, this bearing style can offer designers an op­portunity to reduce the length and weight of the gearbox. Because one instead of two rows are applied, efficiency is im­proved by approximately 30-50%. Since the locator runs constantly with a 360º load zone in all positive torque conditions, shaft movement is minimized and gear contact is no longer a function of the bearing clearance. Concerns for smearing races in un­seated conditions are eliminated. Although there exists very substantial experience with using bi-directional bear­ings like the locator bearing in many different applications, it is important that field testing is performed to validate us­age, since there are many transient conditions in a wind turbine gearbox that remain unaccounted for at the design stage.

Doug Lucas is chief engineer for wind applications at The Timken Company in Canton, Ohio, U.S.

Biswanath Nandi is a former group leader of new product development and design at Timken Engineering and Research India in Bangalore.

Images courtesy The Timken Company

Untitled Document

Get All the Renewable Energy World News Delivered to Your Inbox - FREE!

Subscribe to Renewable Energy World Magazine and our award-winning e-Newsletter to stay up to date on current news and industry trends.

 Subscribe Now


US Senate Democrats Unveil Energy Bill That Restores PTC and Extends ITC

Brian Eckhouse, Bloomberg Senate Democrats unveiled a bill that would provide more tax credits for renewable energy while killing some tax ince...

Sage Grouse Removed as Threat to Biggest Wind Farm in U.S.

Christopher Martin, Bloomberg Billionaire Phil Anschutz’s plans to build a $5 billion wind farm in southeast Wyoming will no longer be stymied by t...

CEO Gilles: Challenge in Geothermal is to 'Level Playing Field' with Wind, Solar

Jennifer Delony The current challenge for the geothermal energy industry is what U.S. Geothermal CEO Dennis Gilles calls “leveling th...

NRG Energy to Form Renewable Unit, Sell Wind Assets to Yieldco

Mark Chediak and Matthew Monks, Bloomberg NRG Energy Inc., the worst-performing member of the S&P 500 Utilities Index this year, said it will form a renewa...


US Solar Hosts Sierra Club Solar Meeting

This past Monday, US Solar welcomed a new group to its solar training classroom – The S...

US Solar Invited to Speak at Intersolar North America

Intersolar, the largest solar conference and expo in North America is right around the ...

US Solar - Green Planet Festival Highlights Solar Energy and Solar Training This Weekend

US Solar Institute (USSI) is excited to announce that they are the educational sponsor ...

Yaskawa – Solectria Solar Provides Inverters for One of the Largest Professional Sport Stadium PV Systems in North America

Yaskawa - Solectria Solar, a leading U.S. PV inverter manufacturer, announced today tha...


Solar Decathlon 2015 Opens to the Public in California

Today, Oct. 8, the biennial Solar Decathlon opened up to the public at Orange County Great Park in Irvine, ...

ENER-G CHP technology selected for major London housing scheme

ENER-G has been selected to supply combined heat and power (CHP) technology for phase two of the Leopold Estate housi...


Necessity is the mother of innovation. Our planet is going through major changes in climate. This of course will affe...

Georgia Legislature Approves PPA’s, Florida Hoping to Follow

Ah, the sunny south, the land of peaches, oranges and solar potential. I’m talking about Georgia and Florida he...


Doug Lucas is chief engineer for wind applications at The Timken Company in Canton, Ohio, U.S.


Volume 18, Issue 4


To register for our free
e-Newsletters, subscribe today:


Tweet the Editors! @jennrunyon



Doing Business in Europe – in partnership with GWEC, the Global Win...

There is now 128.8 GW of installed wind energy capacity in the EU (appro...

JuiceBox Energy Certified Installer Class

JuiceBox Energy is rapidly building out its national certified installer...

Wind Operator Congress Europe

The UK’s only business-focused O&M event for the European wind...


Clean Energy Patents Maintain High Levels in First Quarter, Solar L...

U.S. patents for Clean Energy technologies from the first quarter of 201...

Koch Professor drops his Koch title, still makes same errors plus s...

The Koch Professor’s title isn’t the only thing that’s...

Fact Check: AWEA represents American wind power

The American Wind Energy Association (AWEA) is proud of its members for ...


Renewable Energy: Subscribe Now

Solar Energy: Subscribe Now

Wind Energy: Subscribe Now

Geothermal Energy: Subscribe Now

Bioenergy: Subscribe Now